M204.1525

From m204wiki
Jump to navigation Jump to search

M204.1525  No inbound threads available

Model 204 is attempting to honor a request by a remote partner to open an inbound local process, but there are currently no IODEV 19, 27, or 49 threads available on which to run the process. The remote partner will receive a retryable remote allocation failure indication.

System manager response: Whenever this error occurs, a remote process is failing in an attempt to establish a conversation with the local Model 204 because all IODEV 19, 27, or 49 threads are in use for inbound conversations. If this happens frequently you may wish to increase the number of IODEV for your thread type.

Operator response: Contact your system manager.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console
SAVESaves the message in the VIEW ERRORS table

Back to list of messages