CFRJRNL parameter

From m204wiki
Revision as of 20:03, 30 October 2014 by JAL (talk | contribs) (→‎Description)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

CFR+rec locking stats to CCAJRNL

Summary

Default value
0
Parameter type
System
Where set

On User 0's parameter line

Valid settings of CFRJRNL are shown in the following table.

SettingMeaning
1Journal the statistics.
0Do not journal the statistics.
Related products
All
Introduced
Model 204 V6.1 or earlier

Description

Write to the journal the critical file resource and record locking conflict statistics

The statistics are the following since-last statistics, described in User since-last statistics, which you can display by issuing MONITOR with the CFR option:

BLKCFRE
WTCFR
BLKRLK