M204.0468

From m204wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

M204.0468  Compilation not saved - reason token

The compilation for a precompileable subsystem procedure could not be saved for the indicated reason. The procedure is marked as a non-precompiled procedure for the duration of the subsystem session.

As of Model 204 version 7.6, if reason indicates a problem with a file, token is the file name.

Response: Notify the system manager.

System manager response: Look at the audit trail to determine the name of the procedure in error. Correct the procedure so that it follows all the conventions required for subsystem precompiled procedures.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages