M204.1058  token out of token2 output buffers are active

This is an informational message generated by the MONITOR command. The message displays the number of output buffers in use when the MONITOR command was issued.

System manager response: This information is useful in tuning the Model 204 Online system. If the percentage of active buffers is exceptionally high, increase the NOUTBUF parameter. If the percentage is low, decrease the NOUTBUF parameter. This parameter is on the User 0 line of the CCAIN parameters in the Model 204 Online job. Correct, and rerun.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages