M204.1803

From m204wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

M204.1803  No inbound threads allocated

Model 204 is processing an OPEN LINK command and detects that no server threads were allocated during Model 204 initialization.

System manager response: If the link being opened is defined with TRANSPORT=IUCV, add IODEV 17 statements to the CCAIN file.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages