M204.1875

From m204wiki
Revision as of 19:04, 5 June 2018 by JAL (talk | contribs) (add link)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1875  Unable to reset MODEL to token

The terminal interface attempted to automatically reset the MODEL parameter to token, but the attempt to RESET failed. MODEL is reset to 2.

System manager response: The likely cause of the failure is a value of the LOUTPB parameter that is too small. Correct LOUTPB on the user parameter line in the CCAIN stream.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal

Back to list of messages