M204.2167

From m204wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

M204.2167  A close error has been detected on dataset token

z/OS detected an error during execution of the CLOSE for the specified tape data set.

System manager response: Check the JES joblog for an x14 abend and for the accompanying IECxxxx message to determine the cause of the error. The specified tape data set may be unreadable following this error.

Operator response: Notify the System Manager.

Message attributes:

RETCODEO=8Sets online return code
RETCODEB=8Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
OPRWrites the message to the (operator) console
SAVESaves the message in the VIEW ERRORS table

Back to list of messages