M204.2299

From m204wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

M204.2299  Conflicting parameters​,​ NRMTLOCS and NRMTFILE

The NRMTLOCS and NRMTFILE parameters have conflicting values. Both values must be set to zero, or both values must be greater than zero. In order to run PQO applications, both parameters must be greater than zero.

Response: To run PQO applications, make both parameters greater than zero. If not running PQO applications, make both parameters zero.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages