SEQPDL parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
 
(3 intermediate revisions by one other user not shown)
Line 21: Line 21:
quad code.  
quad code.  
                                    
                                    
The minumum and default value of SEQPDL is 4096 bytes.  The maximum            
The minumum and default value of SEQPDL is 4096 bytes.   
value is 8192 bytes. SEQPDL is a user resettable parameter and can  
 
be set on the user's parameter line or reset by the UTABLE command.                                                               
The maximum value is 8192 bytes.  
The old value, 1024, was hardcoded internally in the Model 204   
 
SEQPDL is a user resettable parameter and can be set on the user's parameter line or reset by the <var>[[UTABLE_command|UTABLE]]</var> command.                                                               
 
Formerly the amount of free space was 1024, which was hardcoded internally in the Model 204   
nucleus.  With 1024 bytes there were edge cases where abends would     
nucleus.  With 1024 bytes there were edge cases where abends would     
break files. SEQPDL is provided to allow enough PDL space so that     
break files, resulting in ERROR 2126 USER'S PUSHDOWN LIST OVERFLOWED. SEQPDL is provided to allow enough PDL space so that     
all of the lower level journaling routines can process error           
all of the lower level journaling routines can process error           
conditions without breaking files.                                     
conditions without breaking files. The default value of SEQPDL adds 3072 bytes of free space.                                     
                                                                                                              
                                                                                                              
<p class="note"><b>Note:</b> In order to avoid getting ERROR 2126 USER'S PUSHDOWN LIST OVERFLOWED, you might need to increase the User Push Down List (using UTABLE LPDLST) by up to 3072 bytes, or more if you specify a value for SEQPDL that is larger than the 4096 default value. </p>
<p class="note"><b>Note:</b> If your applications' actual use of free space in the User Push Down List approaches the limit that you have set in LPDLST, to avoid a PDL overflow you might need to increase the value of LPDLST by up to 3072 bytes (or more if you set a larger value for SEQPDL). </p>


[[Category:Parameters]]
[[Category:Parameters]]
[[Category:System parameters]]
[[Category:System parameters]]

Latest revision as of 10:10, 30 May 2017

Minimum PDL available for sequencer

Summary

Default value
4096
Parameter type
Utable
Where set
On user's parameter line or reset by UTABLE command
Related products
All
Introduced
Model 204 version 7.5

Description

The SEQPDL parameter controls the amount of free space that must be present in the user's Push Down List in order for the SOUL sequencer to proceed with the next quad code.

The minumum and default value of SEQPDL is 4096 bytes.

The maximum value is 8192 bytes.

SEQPDL is a user resettable parameter and can be set on the user's parameter line or reset by the UTABLE command.

Formerly the amount of free space was 1024, which was hardcoded internally in the Model 204 nucleus. With 1024 bytes there were edge cases where abends would break files, resulting in ERROR 2126 USER'S PUSHDOWN LIST OVERFLOWED. SEQPDL is provided to allow enough PDL space so that all of the lower level journaling routines can process error conditions without breaking files. The default value of SEQPDL adds 3072 bytes of free space.

Note: If your applications' actual use of free space in the User Push Down List approaches the limit that you have set in LPDLST, to avoid a PDL overflow you might need to increase the value of LPDLST by up to 3072 bytes (or more if you set a larger value for SEQPDL).