M204.1371 Insufficient main storage for operator message
There was not enough main storage to allocate a block needed to send a message to the operator.
System manager response: Increase the SIZE parameter in your JCL and rerun Model 204.
Operator response: Notify your system manager.
Message attributes:
| RETCODEO=0 | Sets online return code |
|---|---|
| RETCODEB=4 | Sets batch (single user) return code |
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
| AUDITAD | Writes the message with line type AD to the audit trail |
| NOCOUNT | Does not increment the error count (ERCNT) parameter |
| OPR | Writes the message to the (operator) console |
| SAVE | Saves the message in the VIEW ERRORS table |