M204.1978 Storage could not be obtained for remote access
Storage required for PQO control blocks could not be obtained in the client system.
Response: Inform the System Manager.
System manager response: Increase the amount of storage available to the Model 204 Online region.
Message attributes:
| RETCODEO=0 | Sets online return code |
|---|---|
| RETCODEB=4 | Sets batch (single user) return code |
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
| AUDITER | Writes the message with line type ER to the audit trail |
| COUNT | Increments the error count (ERCNT) parameter |