M204.1873: Difference between revisions
		
		
		
		Jump to navigation
		Jump to search
		
|  Automatically generated page update | m add <var>s | ||
| Line 1: | Line 1: | ||
| {{Template:M204.1873 skeleton}} | {{Template:M204.1873 skeleton}} | ||
| <P> | <P> | ||
| The DBCSENV parameter does not have a valid value, so the DBCS parameter dependencies on this would be inconclusive. </P> | The <var>DBCSENV</var> parameter does not have a valid value, so the DBCS parameter dependencies on this would be inconclusive. </P> | ||
| <p> | <p> | ||
| <b>Response:</b> Contact your system manager </p> | <b>Response:</b> Contact your system manager </p> | ||
Latest revision as of 20:23, 13 March 2018
M204.1873 DBCS parameter cannot be reset when DBCSENV=0
The DBCSENV parameter does not have a valid value, so the DBCS parameter dependencies on this would be inconclusive.
Response: Contact your system manager
System manager response: Bring the Model 204 run down, and insert DBCSENV=n in your CCAIN stream; bring the run back up and retry. Values for n are: 
- 1=IBM
- 2=TEPCO
- 3=FUJITSU
- 4=HITACHI
Message attributes:
| RETCODEO=0 | Sets online return code | 
|---|---|
| RETCODEB=4 | Sets batch (single user) return code | 
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter | 
| AUDITER | Writes the message with line type ER to the audit trail | 
| COUNT | Increments the error count (ERCNT) parameter |