M204.2402 Failed to connect with TCP/IP server=token
While opening a TCP/IP link, Model 204 failed to complete an IUCV CONNECT to the IBM TCP/IP service machine named in the message. This message is accompanied by either ERROR 2292 or 2293, which displays the IUCV return code.
System manager response: Make sure that the service machine name in this message matches the z/OS jobname or the z/VM vmid running IBM TCP/IP on your system. If not, you must add a TCPNAME parameter to your CCAIN user-zero stream to specify the correct ID. If the ID is correct, proceed to the accompanying error messages to continue diagnosing the reason for the failure.
Message attributes:
| RETCODEO=0 | Sets online return code |
|---|---|
| RETCODEB=4 | Sets batch (single user) return code |
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
| AUDITER | Writes the message with line type ER to the audit trail |
| COUNT | Increments the error count (ERCNT) parameter |