M204.2480: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
 
m (remove 0 from token0)
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:


<P>
<P>
The <var class="term">token0</var> Horizon PROCESSGROUP definition has not supplied a MODENAME. The default MODENAME obtained from the relevant APPLID or ISTINCLM may or may not be suitable. [[M204.1294]] OPNDST or OPNSEC errors are the expected
The <var class="term">token</var> [[Horizon]] <var>PROCESSGROUP</var> definition has not supplied a <var>MODENAME</var>. The default <var>MODENAME</var> obtained from the relevant APPLID or ISTINCLM may or may not be suitable. [[M204.1294]] OPNDST or OPNSEC errors are the expected
consequence of the second case.</P>
consequence of the second case.</P>
<p>
<p>
<b>Response:</b> Contact the system manager.</p>
<b>Response:</b> Contact the system manager.</p>
<p>
<p>
<b>System manager response:</b> Correct the PROCESSGROUP definition by adding a MODENAME valid for LU62.
<b>System manager response:</b> Correct the <var>PROCESSGROUP</var> definition by adding a <var>MODENAME</var> valid for LU62.
</p>
</p>
{{Template:M204.2480 footer}}
{{Template:M204.2480 footer}}
<!-- skeleton as it was in pdf/MODENAME UNSPECIFIED BY %C AND WILL DEFAULT/-->
<!-- skeleton as it was in pdf/MODENAME UNSPECIFIED BY %C AND WILL DEFAULT/-->

Latest revision as of 22:23, 26 March 2018

M204.2480  MODENAME unspecified by token and will default

The token Horizon PROCESSGROUP definition has not supplied a MODENAME. The default MODENAME obtained from the relevant APPLID or ISTINCLM may or may not be suitable. M204.1294 OPNDST or OPNSEC errors are the expected consequence of the second case.

Response: Contact the system manager.

System manager response: Correct the PROCESSGROUP definition by adding a MODENAME valid for LU62.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages