Latest revision as of 16:26, 27 August 2013
Maximum number of errors
Summary
- Default value
- 30
- Parameter type
- User
- Where set
- By any user
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The maximum number of counting errors before either user restart or processing failure.
- If ERMX is exceeded due to failed commands within a procedure, the user is restarted softly.
- If ERMX is exceeded due to User Language compilation errors, compilation stops and the user is returned to command level.
- If ERMX is exceeded due to User Language evaluation (run time) errors, the request is terminated and the user is restarted softly.
The valid range for setting a limit is 0 to 65535.
Setting a value of -1 or 65535 ignores counting errors and processing continues.