M204.0503: Difference between revisions

From m204wiki
Jump to navigation Jump to search
DmeWiccan (talk | contribs)
Automatically generated page update
 
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Template:M204.0503 skeleton}}
<P>
<P>This message is issued during initialization (IODEV processing) when the TERMBUF parameter is set incorrectly. Model 204 is terminated. TERMBUF should be between 1 (the default) and the value of NOTERM for the line group.
<span class="msgtext">M204.0503&nbsp; INVALID TERMBUF SPECIFICATION <span class="term">
</P>
<P>
This message was removed at 7.6 and is no longer applicable in later versions.
</P>
</P>
<p><b>System manager response:</b> Correct TERMBUF in the CCAIN input and rerun Model 204. </p>
{{Template:M204.0503 footer}}
{{Template:M204.0503 footer}}
<!-- skeleton as it was in pdf/INVALID TERMBUF SPECIFICATION /-->
<!-- skeleton as it was in pdf/INVALID TERMBUF SPECIFICATION /-->

Latest revision as of 19:00, 3 April 2025

M204.0503  INVALID TERMBUF SPECIFICATION

This message was removed at 7.6 and is no longer applicable in later versions.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages