<P>Version 5.1 supports [[ | <P> | ||
<p><b>File manager response:</b> Do one of the following:</p><ol><li>Rerun ROLL BACK/ROLL FORWARD using a pre-Version 5.1 release.</li> | Version 5.1 supports [[System and media recovery#RESTART ROLL FORWARD recovery is version specific|ROLL FORWARD]] recovery for only Version 5.1 journals. The <var>RESTART</var> stream that was specified indicates the recovered run was from a pre-Version 5.1 release.</P> | ||
<p> | |||
<b>File manager response:</b> Do one of the following:</p> | |||
<ol> | |||
<li>Rerun ROLL BACK/ROLL FORWARD using a pre-Version 5.1 release.</li> | |||
<LI>Run only ROLL BACK under Version 5.1.</LI> | <LI>Run only ROLL BACK under Version 5.1.</LI> | ||
</ol> | </ol> | ||
{{Template:M204.2501 footer}} | {{Template:M204.2501 footer}} | ||
<!-- skeleton as it was in pdf/RELEASE INCOMPATIBILITY/--> | <!-- skeleton as it was in pdf/RELEASE INCOMPATIBILITY/--> |
Latest revision as of 21:39, 19 March 2018
M204.2501 Release incompatability
Version 5.1 supports ROLL FORWARD recovery for only Version 5.1 journals. The RESTART stream that was specified indicates the recovered run was from a pre-Version 5.1 release.
File manager response: Do one of the following:
- Rerun ROLL BACK/ROLL FORWARD using a pre-Version 5.1 release.
- Run only ROLL BACK under Version 5.1.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |