M204.2684: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
 
No edit summary
 
Line 1: Line 1:
{{Template:M204.2684 skeleton}}
{{Template:M204.2684 skeleton}}


The possible <var class="term">token0</var> and <var class="term">token2</var> reasons cited for the conflict include the following:
The possible <var class="term">token</var> and <var class="term">token2</var> reasons cited for the conflict include the following:
<ul>
<ul>
<li>[[Checkpoints:_Storing_before-images of changed pages#Creating the CHKPOINT/CHKPNT (and CHKPNTS) data set|CHKPNTS]] is open so CPTIME must be non-zero</li>
<li>[[Checkpoints:_Storing_before-images of changed pages#Creating the CHKPOINT/CHKPNT (and CHKPNTS) data set|CHKPNTS]] is open so CPTIME must be non-zero</li>
Line 25: Line 25:
<P>
<P>
Parameters associated with checkpointing are consistency checked when checkpoint streams are opened, at the beginning of Online processing, and also during the processing of a <var>RESET</var> command. The error indicated in this message was  
Parameters associated with checkpointing are consistency checked when checkpoint streams are opened, at the beginning of Online processing, and also during the processing of a <var>RESET</var> command. The error indicated in this message was  
found, and the result is that the Online failed to come up, or the <var>RESET</var> command was rejected. </P>
found, and the result is that the Online failed to come up, or the <var>[[RESET command|RESET]]</var> command was rejected. </P>
<p class="note"> <b>Note:</b> If <var>CPTYPE</var> is 1, neither CHKPOINT nor CHKPNTS can be defined as a ring stream or a CMS formatted data set.</p>
<p class="note"> <b>Note:</b> If <var>CPTYPE</var> is 1, neither CHKPOINT nor CHKPNTS can be defined as a ring stream or a CMS formatted data set.</p>
<p>
<p>
<b>System manager response:</b> If the Online failed, change the appropriate CCAIN parameter line entries, the CHKPOINT/CHKPNTS stream definitions, or both; if the <var>RESET</var> command failed, take appropriate action.</p>
<b>System manager response:</b> If the Online failed, change the appropriate CCAIN parameter line entries, the CHKPOINT/CHKPNTS stream definitions, or both. If the <var>RESET</var> command failed, take appropriate action.</p>
{{Template:M204.2684 footer}}
{{Template:M204.2684 footer}}
<!-- skeleton as it was in pdf/CHECKPOINT CONFIGURATION CONFLICT -/-->
<!-- skeleton as it was in pdf/CHECKPOINT CONFIGURATION CONFLICT -/-->

Latest revision as of 00:54, 3 April 2018

M204.2684  Checkpoint configuration conflict - token token2

The possible token and token2 reasons cited for the conflict include the following:

  • CHKPNTS is open so CPTIME must be non-zero
  • CHKPNTS is open so DKUPDTWT must be zero
  • A non-TBO file which pre-images but does not journal has been opened for update, sub-transaction CP is not allowed
  • CHKPNTS is not open and CPTYPE = 1
  • CHKPNTS is not open and CPTS is non-zero
  • {CHKPOINT | CHKPNTS} contains a ring definition
  • {CHKPOINT | CHKPNTS} has more than 16 levels of stream definition recursion
  • {CHKPOINT | CHKPNTS} contains a CMS formatted file
  • CHKPNTS is open and journalling not active
  • CPTYPE = 1 is incompatible with NUSERS = 1

Parameters associated with checkpointing are consistency checked when checkpoint streams are opened, at the beginning of Online processing, and also during the processing of a RESET command. The error indicated in this message was found, and the result is that the Online failed to come up, or the RESET command was rejected.

Note: If CPTYPE is 1, neither CHKPOINT nor CHKPNTS can be defined as a ring stream or a CMS formatted data set.

System manager response: If the Online failed, change the appropriate CCAIN parameter line entries, the CHKPOINT/CHKPNTS stream definitions, or both. If the RESET command failed, take appropriate action.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages