SCHDOFL parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
 
(14 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{Template:SCHDOFL parameter subtitle}}
==Summary==
==Summary==
<dl>
<dl>
Line 8: Line 9:
<dd>On User 0's parameter line or reset by system manager.
<dd>On User 0's parameter line or reset by system manager.
<dt>Related products
<dt>Related products
<dd>All
<dd><var>[[MP/204#Multiprocessing_.28MP.2F204.29|MP/204]]</var>
<dt>Introduced
<dt>Introduced
<dd><var class="product">Model 204 V7.4</var>
<dd><var class="product">Model 204 V7.4</var> ( was available in previous releases but wasn't documented )
</dl>
</dl>
==Description==
==Description==
<p>Specifies the target number of threads on the MP offload queue per active task. Setting this parameter makes the <var class="product">Model&nbsp;204</var> MP subtask scheduler more responsive to instantaneous increases in load.</p>
<p>
<p>The default value of 2 means that if there are more than twice as many units of MP offloadable work waiting to be processed in an MP subtask as there are active subtasks, and fewer than AMPSUBS subtasks are currently running, another MP offload subtask is activated. </p>
This parameter specifies the target number of threads on the MP offload queue per active task. Setting this parameter makes the <var class="product">Model&nbsp;204</var> MP subtask scheduler more responsive to instantaneous increases in load, though it has the potential to start MP subtasks too frequently, thus incurring high wait, post, and address space dispatch costs.</p>
<p>SCHDOFL has no effect if MP/204 is not in effect in an Online (NMPSUBS=0) or if the number of active subtasks (AMPSUBS) is set to 0 or 1. (If AMPSUBS=1, an MP subtask is activated as soon as there is any offloadable work and then runs until there is no more offloadable work for it to process.)</p>
<p>
The default value of 2 means that if there are more than twice as many units of MP offloadable work waiting to be processed in an MP subtask as there are active subtasks, and fewer than <var>[[AMPSUBS_parameter|AMPSUBS]]</var> subtasks are currently running, another MP offload subtask is activated. </p>
<p>
<var>SCHDOFL</var> has no effect if either of these is true: </p>
<ul>
<li>MP/204 is not in effect in an Online (<var>[[NMPSUBS_parameter|NMPSUBS]]</var> is 0).</li>
 
<li>The number of active subtasks (<var>AMPSUBS</var>) is set to 0 or 1. (If <var>AMPSUBS</var> is 1, an MP subtask is activated as soon as there is any offloadable work, and it then runs until there is no more offloadable work for it to process.)</li>
</ul>
<p>
<var>[[SCHDOFLZ parameter|SCHDOFLZ]]</var> performs the same function as <var>SCHDOFL</var> for <var>[[Performance_monitoring_and_tuning#Offloading_Model_204_work_to_zIIP_processors|zIIP]]</var> (SRB) subtasks. <var>[[SCHDOFLS parameter|SCHDOFLS]]</var> controls how aggressively MP subtasks are started to help out zIIP subtasks, and how aggressively MP subtasks take work from zIIP subtasks. </p>
<p>
Prior to Model 204 7.7, the minimum allowed value for <var>SCHDOFL</var> is 1. Under Model 204 7.7 and later, it is 0, though it is probably a bad idea to set <var>SCHDOFL</var> to 0 unless the <var>[[MPDELAY parameter|MPDELAY]]</var> parameter is set to a non-zero value.
</p>
 
[[Category:System parameters]]
[[Category:System parameters]]
[[Category:Parameters]]
[[Category:Parameters]]

Latest revision as of 11:31, 24 May 2017

Threshold for activating subtasks

Summary

Default value
2
Parameter type
System
Where set
On User 0's parameter line or reset by system manager.
Related products
MP/204
Introduced
Model 204 V7.4 ( was available in previous releases but wasn't documented )

Description

This parameter specifies the target number of threads on the MP offload queue per active task. Setting this parameter makes the Model 204 MP subtask scheduler more responsive to instantaneous increases in load, though it has the potential to start MP subtasks too frequently, thus incurring high wait, post, and address space dispatch costs.

The default value of 2 means that if there are more than twice as many units of MP offloadable work waiting to be processed in an MP subtask as there are active subtasks, and fewer than AMPSUBS subtasks are currently running, another MP offload subtask is activated.

SCHDOFL has no effect if either of these is true:

  • MP/204 is not in effect in an Online (NMPSUBS is 0).
  • The number of active subtasks (AMPSUBS) is set to 0 or 1. (If AMPSUBS is 1, an MP subtask is activated as soon as there is any offloadable work, and it then runs until there is no more offloadable work for it to process.)

SCHDOFLZ performs the same function as SCHDOFL for zIIP (SRB) subtasks. SCHDOFLS controls how aggressively MP subtasks are started to help out zIIP subtasks, and how aggressively MP subtasks take work from zIIP subtasks.

Prior to Model 204 7.7, the minimum allowed value for SCHDOFL is 1. Under Model 204 7.7 and later, it is 0, though it is probably a bad idea to set SCHDOFL to 0 unless the MPDELAY parameter is set to a non-zero value.