LOCATION parameter: Difference between revisions
m (link repair) |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Template:LOCATION parameter subtitle}} | |||
==Summary== | ==Summary== | ||
<dl> | <dl> | ||
Line 10: | Line 11: | ||
<dd>All | <dd>All | ||
<dt>Introduced | <dt>Introduced | ||
<dd><var class="product">Model 204 | <dd><var class="product">Model 204 V3.2</var> or earlier | ||
</dl> | </dl> | ||
==Description== | ==Description== | ||
<p> | <p> | ||
<p>The LOCATION parameter is specific to PQO users. It is required for <i>both</i> clients and servers. The LOCATION value must be unique and from one to eight characters in length. </p> | <var>LOCATION</var> specifies the locally known name of a node (copy of <var class="product">Model 204</var>) in a <var class="product">[[Introduction to User Language#Parallel Query Option/204|Parallel Query Option/204]]</var> (PQO) network </p> | ||
<p>The LOCATION parameter is used internally, is displayed to identify client users when a service thread issues a LOGWHO command, and is used with BUMP SUBSYSTEM, MONITOR SUBSYSTEM, and STOP SUBSYSTEM to identify a service subsystem by its associated client. </p> | <p> | ||
<p>The LOCATION parameter value does <i>not</i> have to match the value specified for any DEFINE FILE command LOCATION parameter or for any remote file specification (filename AT location). </p> | The <var>LOCATION</var> parameter is specific to PQO users. It is required for <i>both</i> clients and servers. The <var>LOCATION</var> value must be unique and from one to eight characters in length. </p> | ||
<p>LOCATION is viewable with VIEW but is not resettable. </p> | <p> | ||
[[Category:System | The <var>LOCATION</var> parameter is used internally, is displayed to identify client users when a service thread issues a <var>[[LOGWHO command|LOGWHO]]</var> command, and is used with <var>[[BUMP command|BUMP SUBSYSTEM]]</var>, <var>[[MONITOR command: Subsystems|MONITOR SUBSYSTEM]]</var>, and <var>[[STOP command: Stopping an application subsystem|STOP SUBSYSTEM]]</var> to identify a service subsystem by its associated client. </p> | ||
<p> | |||
The <var>LOCATION</var> parameter value does <i>not</i> have to match the value specified for any <var>[[DEFINE FILE command|DEFINE FILE]]</var> command <var>LOCATION</var> parameter or for any remote file specification (<var><i>filename</i> AT <i>location</i></var>). </p> | |||
<p> | |||
<var>LOCATION</var> is viewable with <var>[[VIEW command|VIEW]]</var>, but it is not resettable. </p> | |||
[[Category:System parameters]] | |||
[[Category:Parameters]] | [[Category:Parameters]] |
Latest revision as of 17:45, 9 January 2015
D204 location
Summary
- Default value
- None
- Parameter type
- System
- Where set
- On User 0's parameter line
- Related products
- All
- Introduced
- Model 204 V3.2 or earlier
Description
LOCATION specifies the locally known name of a node (copy of Model 204) in a Parallel Query Option/204 (PQO) network
The LOCATION parameter is specific to PQO users. It is required for both clients and servers. The LOCATION value must be unique and from one to eight characters in length.
The LOCATION parameter is used internally, is displayed to identify client users when a service thread issues a LOGWHO command, and is used with BUMP SUBSYSTEM, MONITOR SUBSYSTEM, and STOP SUBSYSTEM to identify a service subsystem by its associated client.
The LOCATION parameter value does not have to match the value specified for any DEFINE FILE command LOCATION parameter or for any remote file specification (filename AT location).
LOCATION is viewable with VIEW, but it is not resettable.