JOBSTEP parameter: Difference between revisions
(2 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
{{Template:JOBSTEP parameter subtitle}} | |||
==Summary== | ==Summary== | ||
<dl> | <dl> | ||
Line 13: | Line 14: | ||
</dl> | </dl> | ||
==Description== | ==Description== | ||
<p> The JOBSTEP parameter | <p> The JOBSTEP parameter will have a blank value unless you are executing a JCL PROC.</p> | ||
<p>When <var class="product">Model 204</var> runs as part of a JCL PROC, and you execute the same JCL PROC repeatedly in a given JCL stream, you can identify each JCL PROC by its JOBSTEP value.</p> | <p>When <var class="product">Model 204</var> runs as part of a JCL PROC, and you execute the same JCL PROC repeatedly in a given JCL stream, you can identify each JCL PROC by its JOBSTEP value.</p> | ||
<p>JOBSTEP: the JOBSTEP name on the EXEC JCL card that runs the JCL PROC.</p> | <p>JOBSTEP: the JOBSTEP name on the EXEC JCL card that runs the JCL PROC.</p> | ||
<p>STEPNM (if JOBSTEP is not blank): the name on the EXEC JCL card that specifies the module name in the PGM=JCL parameter.</p> | <p><var>[[STEPNM_parameter|STEPNM]]</var> (if JOBSTEP is not blank): the name on the EXEC JCL card that specifies the module name in the PGM=JCL parameter.</p> | ||
<p>Example:</p> | <p>Example:</p> | ||
<p class="code">//PROCNM PROC ZGM=ONLINE | <p class="code">//PROCNM PROC ZGM=ONLINE | ||
Line 30: | Line 31: | ||
</p> | </p> | ||
The JOBSTEP parameter also appears in the informational message M204.0061 during system initialization. | The JOBSTEP parameter also appears in the informational message M204.0061 during system initialization. | ||
[[Category:System | [[Category:System parameters]] | ||
[[Category:Parameters]] | [[Category:Parameters]] |
Latest revision as of 15:47, 28 October 2014
Job step name
Summary
- Default value
- None
- Parameter type
- System
- Where set
- View-only
- Related products
- All
- Introduced
- Model 204 V7.4
Description
The JOBSTEP parameter will have a blank value unless you are executing a JCL PROC.
When Model 204 runs as part of a JCL PROC, and you execute the same JCL PROC repeatedly in a given JCL stream, you can identify each JCL PROC by its JOBSTEP value.
JOBSTEP: the JOBSTEP name on the EXEC JCL card that runs the JCL PROC.
STEPNM (if JOBSTEP is not blank): the name on the EXEC JCL card that specifies the module name in the PGM=JCL parameter.
Example:
//PROCNM PROC ZGM=ONLINE //ONLINE EXEC PGM=&ZGM, <<<<< STEPNM parameter value .... // PEND //JOBSTNM EXEC PROCNM ZGM=ONLINE <<<< JOBSTEP parameter value .... V JOBSTEP JOBSTEP JOBSTNM JOB STEP NAME V STEPNM STEPNM ONLINE STEP NAME
The JOBSTEP parameter also appears in the informational message M204.0061 during system initialization.