LITBL parameter: Difference between revisions
Jump to navigation
Jump to search
m (Add rounding to 8. Add the message you will sometimes get when changing from 0 to a larger number. (But why does that only seem to happen when increasing and not decreasing?)) |
|||
(4 intermediate revisions by 3 users not shown) | |||
Line 3: | Line 3: | ||
<dl> | <dl> | ||
<dt>Default value | <dt>Default value | ||
<dd>0 | <dd>8 (as of version 7.7) <br /> | ||
0 (in version 7.6 or earlier) | |||
<dt>Parameter type | <dt>Parameter type | ||
<dd>Utable | <dd>Utable | ||
Line 15: | Line 16: | ||
==Description== | ==Description== | ||
<p><var>LITBL</var> specifies the size of ITBL in bytes.</p> | <p> | ||
<p><var>LITBL</var> is used to store dummy string and <var>[[$Read]]</var> responses entered on <var>[[INCLUDE command|INCLUDE]]</var> lines. <var>LITBL</var> | <var>LITBL</var> specifies the size of [[Large request considerations#ITBL (dummy string and $READ response table)|ITBL]] in bytes.</p> | ||
<p><var>LITBL</var> | <p> | ||
<p> | <var>LITBL</var> is used to store dummy string and <var>[[$Read]]</var> responses entered on <var>[[INCLUDE command|INCLUDE]]</var> lines.</p> | ||
M204.0102: LITBL reset clears stacked arguments | <p>The minimum value of <var>LITBL</var> is 8 (as of version 7.7). (In version 7.6 or earlier, the minimum is 0.)</p> | ||
M204.1076: Do you really want to CONTINUE | <p>The <var>LITBL</var> value is rounded up to a multiple of 8, with a maximum value of 32760.</p> | ||
<p> | |||
Verification messages may be issued if you are decreasing the size of ITBL and data will be lost (see [[UTABLE command]] for a discussion of changing the size of parameters controlled by the <var>UTABLE</var> command):</p> | |||
<p class="code">M204.0102: LITBL reset clears stacked arguments | |||
M204.1076: Do you really want to CONTINUE</p> | |||
[[Category:Utable parameters]] | [[Category:Utable parameters]] | ||
[[Category:Parameters]] | [[Category:Parameters]] |
Latest revision as of 19:23, 23 June 2016
Length of ITBL
Summary
- Default value
- 8 (as of version 7.7)
0 (in version 7.6 or earlier) - Parameter type
- Utable
- Where set
- On user's parameter line or reset by UTABLE command
- Related products
- All
- Introduced
- Model 204 V2.2 or earlier
Description
LITBL specifies the size of ITBL in bytes.
LITBL is used to store dummy string and $Read responses entered on INCLUDE lines.
The minimum value of LITBL is 8 (as of version 7.7). (In version 7.6 or earlier, the minimum is 0.)
The LITBL value is rounded up to a multiple of 8, with a maximum value of 32760.
Verification messages may be issued if you are decreasing the size of ITBL and data will be lost (see UTABLE command for a discussion of changing the size of parameters controlled by the UTABLE command):
M204.0102: LITBL reset clears stacked arguments M204.1076: Do you really want to CONTINUE