Summary
- Description
- The IFATTN call (ATTENTION) sends an attention interrupt signal.
- Thread type
- IFDIAL
- IFCALL function number
- 43
Syntax
IFATTN(RETCODE)
- Compile-only form
- Not available
- Execute-only form
- Not available
Parameter | Description |
---|---|
RETCODE | [O,i,r] The Model 204 return code is the required output parameter. The code is a binary integer value. |
Usage notes
Use the IFATTN call only with an IFDIAL connection.
The IFATTN call can be issued when a completion code of 1, 2, or 12 is returned from the previous call to IFREAD or IFWRITE call.
When the IFATTN call is issued, any current SOUL request is purged. Follow IFATTN with IFWRITE if processing is to continue.
Completion return code (RETCODE)
If the IFATTN call is unsuccessful, Model 204 returns an error code of 4 if the connection was lost.
Coding example (COBOL)
. . . PROCEDURE DIVISION. . . . CALL "IFATTN" USING RETCODE.