M204.0156: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add <var>'s) |
||
Line 1: | Line 1: | ||
{{Template:M204.0156 skeleton}} | {{Template:M204.0156 skeleton}} | ||
<P>The checkpoint ID specified on the RESTART command is not in the date and time format recognized by Model 204. This ID should be in the following format: </P><P class="code">yy.ddd hh:mm:ss </P> | <P> | ||
<P>Use the precise format | The checkpoint ID specified on the <var>RESTART</var> command is not in the date and time format recognized by Model 204. This ID should be in the following format: </P> | ||
<p><b>System manager response:</b> Correct the ID specification in User 0 and rerun Model 204. </p> | <P class="code">yy.ddd hh:mm:ss </P> | ||
<P> | |||
Use the precise format shown on the audit trail from which this ID was obtained. </P> | |||
<p> | |||
<b>System manager response:</b> Correct the ID specification in User 0, and rerun Model 204. | |||
</p> | |||
{{Template:M204.0156 footer}} | {{Template:M204.0156 footer}} | ||
<!-- skeleton as it was in pdf/INVALID CHECKPOINT DATE OR TIME: date or time /--> | <!-- skeleton as it was in pdf/INVALID CHECKPOINT DATE OR TIME: date or time /--> |
Latest revision as of 22:22, 15 February 2018
M204.0156 Invalid checkpoint date or time: dateOrTime
The checkpoint ID specified on the RESTART command is not in the date and time format recognized by Model 204. This ID should be in the following format:
yy.ddd hh:mm:ss
Use the precise format shown on the audit trail from which this ID was obtained.
System manager response: Correct the ID specification in User 0, and rerun Model 204.
Message attributes:
RETCODEO=52 | Sets online return code |
---|---|
RETCODEB=52 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |