NOTERM is a user parameter that specifies the number of IODEV | <var>[[NOTERM parameter|NOTERM]]</var> is a user parameter that specifies the number of <var>IODEV</var> lines or the number of terminal connections in the Model 204 Online job. For <var>IODEV</var> 7 or 37 threads, the parameter <var>NOTERM</var> is set on the first <var>IODEV</var> parameter statement. If the value of <var>NOTERM</var> is missing or a negative number, or if <var>NOTERM</var> is set to some other value on an <var>IODEV</var> statement other than the first <var>IODEV</var> statement, this message will appear. </P> | ||
<P> | <P> | ||
Verify that the number of <var>IODEV</var> lines for each type 7 or 37 line matches the value specified in the <var>NOTERM</var> parameter on the first <var>IODEV</var> statement of each type. Correct the parameter, and rerun Model 204. | |||
</P> | |||
{{Template:M204.0197 footer}} | {{Template:M204.0197 footer}} | ||
<!-- skeleton as it was in pdf/INVALID NOTERM VALUE /--> | <!-- skeleton as it was in pdf/INVALID NOTERM VALUE /--> |
Latest revision as of 21:42, 15 February 2018
M204.0197 Invalid NOTERM value
NOTERM is a user parameter that specifies the number of IODEV lines or the number of terminal connections in the Model 204 Online job. For IODEV 7 or 37 threads, the parameter NOTERM is set on the first IODEV parameter statement. If the value of NOTERM is missing or a negative number, or if NOTERM is set to some other value on an IODEV statement other than the first IODEV statement, this message will appear.
Verify that the number of IODEV lines for each type 7 or 37 line matches the value specified in the NOTERM parameter on the first IODEV statement of each type. Correct the parameter, and rerun Model 204.
Message attributes:
RETCODEO=80 | Sets online return code |
---|---|
RETCODEB=80 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |