<P>Table B, the data portion of a Model 204 file, is completely full. No further records can be added to the file. The File Load program which produced this error has been ended. </P>
<P>
<p><b>File manager response:</b> Reorganize this file allocating additional pages (parameter BSIZE) or more records per page (BRECPPG) to the Table B section of the file. </p>
Table B, the data portion of a Model 204 file, is completely full. No further records can be added to the file. The File Load program which produced this error has been ended. </P>
<p>
<b>File manager response:</b> Reorganize this file allocating additional pages (parameter <var>BSIZE</var>) or more records per page (<var>BRECPPG</var>) to the Table B section of the file.  
</p>
{{Template:M204.0707 footer}}
{{Template:M204.0707 footer}}
<!-- skeleton as it was in pdf/TABLE B FULL -- APPENDS /-->
<!-- skeleton as it was in pdf/TABLE B FULL -- APPENDS /-->

Latest revision as of 23:38, 27 February 2018

M204.0707  Table B full -- appends

Table B, the data portion of a Model 204 file, is completely full. No further records can be added to the file. The File Load program which produced this error has been ended.

File manager response: Reorganize this file allocating additional pages (parameter BSIZE) or more records per page (BRECPPG) to the Table B section of the file.

Message attributes:

RETCODEO=48Sets online return code
RETCODEB=48Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter