A HALT command is being processed and the text specified for the message or reply field of the HALT message is not equal to the length specified. This message is followed by a COMMAND REJECTED message. If an | A <var>HALT</var> command is being processed and the text specified for the message or reply field of the <var>HALT</var> message is not equal to the length specified. This message is followed by a <code>COMMAND REJECTED</code> message. If an <var>If/Then</var> | ||
statement in SOUL is being processed, the statement has incorrect syntax. Compilation continues but the request is not executed.</P> | statement in SOUL is being processed, the statement has incorrect syntax. Compilation continues but the request is not executed.</P> | ||
<p> | <p> | ||
<b>Response:</b> If an | <b>Response:</b> If an <var>If/Then</var> statement produces the message, correct the syntax and retry the request.</p> | ||
<p> | <p> | ||
<b>System manager response:</b> If a HALT command produces the message, recalculate the length or change the text in the MESSAGE or REPLY field to conform to the length specified. Then retry the command.</p> | <b>System manager response:</b> If a <var>HALT</var> command produces the message, recalculate the length or change the text in the <code>MESSAGE</code> or <code>REPLY</code> field to conform to the length specified. Then retry the command. | ||
</p> | |||
{{Template:M204.0732 footer}} | {{Template:M204.0732 footer}} | ||
<!-- skeleton as it was in pdf/FORMAT ERROR/--> | <!-- skeleton as it was in pdf/FORMAT ERROR/--> |
Latest revision as of 23:38, 1 March 2018
M204.0732 Format error
A HALT command is being processed and the text specified for the message or reply field of the HALT message is not equal to the length specified. This message is followed by a COMMAND REJECTED
message. If an If/Then
statement in SOUL is being processed, the statement has incorrect syntax. Compilation continues but the request is not executed.
Response: If an If/Then statement produces the message, correct the syntax and retry the request.
System manager response: If a HALT command produces the message, recalculate the length or change the text in the MESSAGE
or REPLY
field to conform to the length specified. Then retry the command.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |