M204.1158: Difference between revisions
(Automatically generated page update) |
m (add link) |
||
Line 1: | Line 1: | ||
{{Template:M204.1158 skeleton}} | {{Template:M204.1158 skeleton}} | ||
<P> | <P> | ||
The procedure cannot be displayed or copied for one of the following reasons: </P> | The <var class="term">token2</var> procedure cannot be displayed or copied for one of the following reasons: </P> | ||
<ul> | <ul> | ||
<li>The specified procedure does not exist. </li> | <li>The specified procedure does not exist. </li> | ||
Line 15: | Line 13: | ||
<b>Response:</b> Check for misspelling, wait until the procedure is not in use by someone else, or have the file manager grant you access to this procedure. </p> | <b>Response:</b> Check for misspelling, wait until the procedure is not in use by someone else, or have the file manager grant you access to this procedure. </p> | ||
<p> | <p> | ||
<b>File manager response:</b> Consider giving the user access to display or copy this procedure. If the user has access to the procedure and it is a | <b>File manager response:</b> Consider giving the user access to display or copy this procedure. If the user has access to the procedure and it is a [[SECURE PROCEDURE ACCESS command|secured]] procedure, check that the user has access to the same PCLASS in the output file. | ||
</p> | |||
{{Template:M204.1158 footer}} | {{Template:M204.1158 footer}} | ||
<!-- skeleton as it was in pdf/CAN'T action PROCEDURE: procname /--> | <!-- skeleton as it was in pdf/CAN'T action PROCEDURE: procname /--> |
Latest revision as of 22:25, 5 March 2018
M204.1158 Can't token procedure: token2
The token2 procedure cannot be displayed or copied for one of the following reasons:
- The specified procedure does not exist.
- The specified procedure is being modified.
- You do not have proper authority to display or copy this procedure.
- You do no have proper authority to copy into this procedure.
If an attempt is made to copy or display multiple procedures and the first attempt fails, M204.1158 is issued only once (as of version 7.6). This avoids issuing the same message numerous times for all remaining procedures and possibly exceeding ERMX, which could result in a user restart. No attempt is made to copy or display the remaining procedures.
Response: Check for misspelling, wait until the procedure is not in use by someone else, or have the file manager grant you access to this procedure.
File manager response: Consider giving the user access to display or copy this procedure. If the user has access to the procedure and it is a secured procedure, check that the user has access to the same PCLASS in the output file.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |