An I/O error (INPUT or OUTPUT) was encountered while reading from the input stream/data set or while writing to the output stream/data set. The COPY action is terminated and, if possible, both input and output streams are closed.  </P>
An I/O error (INPUT or OUTPUT) was encountered while reading from the input stream/data set or while writing to the output stream/data set. The <var>COPY</var> action is terminated and, if possible, both input and output streams are closed.   
</P>
{{Template:M204.1853 footer}}
{{Template:M204.1853 footer}}
<!-- skeleton as it was in pdf/ I/O ERROR ON iotype, COPY COMMAND FAILED /-->
<!-- skeleton as it was in pdf/ I/O ERROR ON iotype, COPY COMMAND FAILED /-->

Revision as of 19:03, 13 March 2018

M204.1853  I​/​O error on ddName​,​ COPY command failed

An I/O error (INPUT or OUTPUT) was encountered while reading from the input stream/data set or while writing to the output stream/data set. The COPY action is terminated and, if possible, both input and output streams are closed.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter