M204.2736: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
 
No edit summary
 
Line 2: Line 2:


<P>
<P>
You issued the <var>INITIALIZE</var> command for the <var class="term">filename</var> file with date/time stamp updates. Since the <var>KEEPDEFS</var> option was not specified, <var>INITIALIZE</var> processing removed field definitions. This disabled the date/time stamp feature (<var>FOPT</var> X'10').</P>
You issued the <var>[[INITIALIZE command|INITIALIZE]]</var> command for the <var class="term">fileName</var> file with date/time stamp updates. Since the <var>KEEPDEFS</var> option was not specified, <var>INITIALIZE</var> processing removed field definitions. This disabled the date/time stamp feature (<var>[[FOPT parameter|FOPT]]</var> X'10').</P>


<p>
<p>

Latest revision as of 23:48, 20 March 2018

M204.2736  File fileName FOPT​=​x'10' turned off: date time stamp field undefined

You issued the INITIALIZE command for the fileName file with date/time stamp updates. Since the KEEPDEFS option was not specified, INITIALIZE processing removed field definitions. This disabled the date/time stamp feature (FOPT X'10').

File manager response: Define the date/time stamp field, and reset FOPT to include X'10'.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages