M204.2156: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (remove 0 from token0) |
||
Line 2: | Line 2: | ||
<P> | <P> | ||
A <var>*TRACE</var> command failed because there was not enough storage to allocate a message buffer control block. <var class="term"> | A <var>*TRACE</var> command failed because there was not enough storage to allocate a message buffer control block. <var class="term">token</var> is the return code Model 204 received from CMS when trying to allocate the storage. For CMS Release 5, refer to the <code>DMSFREE</code> macro return codes. For CMS Release 5.5 and above, refer to the <code>CMSSTOR</code> macro return codes. </P> | ||
refer to the <code>DMSFREE</code> macro return codes. For CMS Release 5.5 and above, refer to the <code>CMSSTOR</code> macro return codes. </P> | |||
<p> | <p> | ||
<b>System manager response:</b> Increase the value of the <var>SPCORE</var> parameter or decrease <var>MAXBUF</var> in the CCAIN stream to ensure enough space is available to run the tracing facility. </p> | <b>System manager response:</b> Increase the value of the <var>SPCORE</var> parameter or decrease <var>MAXBUF</var> in the CCAIN stream to ensure enough space is available to run the tracing facility. | ||
</p> | |||
{{Template:M204.2156 footer}} | {{Template:M204.2156 footer}} | ||
<!-- skeleton as it was in pdf/UNABLE TO ALLOCATE SUFFICIENT STORAGE FOR MESSAGE BUFFER: RC = return_code /--> | <!-- skeleton as it was in pdf/UNABLE TO ALLOCATE SUFFICIENT STORAGE FOR MESSAGE BUFFER: RC = return_code /--> |
Latest revision as of 21:37, 26 March 2018
M204.2156 Unable to allocate sufficient storage for message buffer: rc = token
A *TRACE command failed because there was not enough storage to allocate a message buffer control block. token is the return code Model 204 received from CMS when trying to allocate the storage. For CMS Release 5, refer to the DMSFREE
macro return codes. For CMS Release 5.5 and above, refer to the CMSSTOR
macro return codes.
System manager response: Increase the value of the SPCORE parameter or decrease MAXBUF in the CCAIN stream to ensure enough space is available to run the tracing facility.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |