FDWOL (JANUS DEFINE parameter): Difference between revisions

From m204wiki
Jump to navigation Jump to search
m (1 revision)
m (1 revision)
Line 4: Line 4:
<var>FDWOL</var> is a parameter on [[JANUS DEFINE]], which defines and sets characteristics of a Janus port.  
<var>FDWOL</var> is a parameter on [[JANUS DEFINE]], which defines and sets characteristics of a Janus port.  


This parameter specifies that all FINDs done by the <var class="product">[http://sirius-software.com/maint/download/sdsr.pdf Janus Specialty Data Store]</var> are to be done as FIND WITHOUT LOCKS. This can minimize the impact of ''Janus Specialty Data Store'' applications on 3270 applications and reduce record locking conflicts caused by large <var class="product">Janus Specialty Data Store</var> request. On the other hand, <var>FDWOL</var> could cause severe ''Model 204'' errors especially in reuse record number files. The default for <var>[[JANUS DEFINE#type|SDS]]</var> ports is no <var>FDWOL</var>.  
This parameter specifies that all FINDs done by the <var class="product">[http://sirius-software.com/maint/download/sdsr.pdf Janus Specialty Data Store]</var> are to be done as FIND WITHOUT LOCKS. This can minimize the impact of ''Janus Specialty Data Store'' applications on 3270 applications and reduce record locking conflicts caused by large <var class="product">Janus Specialty Data Store</var> request. On the other hand, <var>FDWOL</var> could cause severe <var class="product">Model 204</var> errors especially in reuse record number files. The default for <var>[[JANUS DEFINE#type|SDS]]</var> ports is no <var>FDWOL</var>.  


Valid only for <var>SDS</var> (also known as <var>[[JANUS DEFINE#type|OMNI]]</var> and OAS) ports.
Valid only for <var>SDS</var> (also known as <var>[[JANUS DEFINE#type|OMNI]]</var> and OAS) ports.

Revision as of 21:15, 1 March 2012

<section begin="desc" />Do Find Without Locks on SDS ports<section end="desc" />

FDWOL is a parameter on JANUS DEFINE, which defines and sets characteristics of a Janus port.

This parameter specifies that all FINDs done by the Janus Specialty Data Store are to be done as FIND WITHOUT LOCKS. This can minimize the impact of Janus Specialty Data Store applications on 3270 applications and reduce record locking conflicts caused by large Janus Specialty Data Store request. On the other hand, FDWOL could cause severe Model 204 errors especially in reuse record number files. The default for SDS ports is no FDWOL.

Valid only for SDS (also known as OMNI and OAS) ports.

See also