Revision as of 14:14, 19 April 2013
Summary
- Default value
- 0
- Parameter type
- System
- Where set
- On User 0's parameter line or reset by system manager
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The internal priority increment associated with aging promotion
Each time an aging scan determines that a particular user has waited longer than AGEINTVL milliseconds, it assigns a multiplier, as explained in the description of AGEINTVL.
This multiplier is applied to AGEINCR and the result is added to the user's current internal priority, subject to the PRIOMAX parameter. Increasing this parameter causes the user's priority to increase faster with aging.
Do not set AGEINCR greater than PRIOMAX, because this prevents the user's pre-aged priority from being altered.