Revision as of 14:06, 4 August 2015
Max connect time
Summary
- Default value
- 86400
- Parameter type
- User
- Where set
- By any user
- Related products
- All
- Introduced
- Model 204 V8.1 or earlier
Description
The maximum wall clock time in seconds per request
At certain points during loop processing of a request, the elapsed wall clock time of the request is compared to the value of MCNCT. If the elapsed time is greater, you are informed that the request is long. You can either continue or cancel the request.
In batch jobs, in application subsystems, or if the value of the PROMPT parameter includes the hexadecimal 10 option, this interaction with you does not happen and the request is canceled.
The maximum MCNCT value is 2,147,483,647.