Revision as of 13:55, 28 September 2017

Time allowed for termination

Summary

Default value
1500
Parameter type
System
Where set
On User 0's parameter line
Related products
All
Introduced
Model 204 V2.1 or earlier

Description

The point at which Model 204 automatically terminates the run

The run ends when the number of CPU milliseconds left for the run equals the setting of TIMESTOP. To initiate a command or User Language request, the milliseconds remaining must be twice the value of TIMESTOP.

Files can be logically inconsistent after automatic termination. Use of the ROLL BACK and ROLL FORWARD facilities ensures the logical consistency of files.

If TIMESTOP is set to 0, the Model 204 timing facility's automatic shutdown is bypassed. If, in addition, the JCL EXEC statement parameter TIME is set to 1440 (24 hours), the z/OS automatic shutdown is bypassed, and Model 204 continues to run indefinitely until brought down by other means.