SEQPDL parameter: Difference between revisions
Line 21: | Line 21: | ||
quad code. | quad code. | ||
The minumum and default value of SEQPDL is 4096 bytes. The maximum | The minumum and default value of SEQPDL is 4096 bytes. | ||
value is 8192 bytes. | |||
be set on the user's parameter line or reset by the UTABLE command. | The maximum value is 8192 bytes. | ||
SEQPDL is a user resettable parameter and can be set on the user's parameter line or reset by the UTABLE command. | |||
The old value, 1024, was hardcoded internally in the Model 204 | The old value, 1024, was hardcoded internally in the Model 204 | ||
nucleus. With 1024 bytes there were edge cases where abends would | nucleus. With 1024 bytes there were edge cases where abends would | ||
break files. SEQPDL is provided to allow enough PDL space so that | break files. SEQPDL is provided to allow enough PDL space so that | ||
all of the lower level journaling routines can process error | all of the lower level journaling routines can process error | ||
conditions without breaking files. | conditions without breaking files. By default the value of SEQPDL adds 3072 bytes of free space. | ||
<p class="note"><b>Note:</b> | <p class="note"><b>Note:</b> If your applications' actual use of free space in the User Push Down List approaches the limit that you have set in LPDLST, you might need to increase the value of LPDLST by up to 3072 bytes (or more if you set a value for SEQPDL that is larger than the default of 4096). Otherwise you could get this error: | ||
ERROR 2126 USER'S PUSHDOWN LIST OVERFLOWED | |||
[[Category:Parameters]] | [[Category:Parameters]] | ||
[[Category:System parameters]] | [[Category:System parameters]] |
Revision as of 00:16, 4 September 2013
Minimum PDL available for sequencer
Summary
- Default value
- 4096
- Parameter type
- Utable
- Where set
- On user's parameter line or reset by UTABLE command
- Related products
- All
- Introduced
- Model 204 version 7.5
Description
The SEQPDL parameter controls the amount of free space that must be present in the user's Push Down List in order for the SOUL sequencer to proceed with the next quad code.
The minumum and default value of SEQPDL is 4096 bytes.
The maximum value is 8192 bytes.
SEQPDL is a user resettable parameter and can be set on the user's parameter line or reset by the UTABLE command.
The old value, 1024, was hardcoded internally in the Model 204 nucleus. With 1024 bytes there were edge cases where abends would break files. SEQPDL is provided to allow enough PDL space so that all of the lower level journaling routines can process error conditions without breaking files. By default the value of SEQPDL adds 3072 bytes of free space.
Note: If your applications' actual use of free space in the User Push Down List approaches the limit that you have set in LPDLST, you might need to increase the value of LPDLST by up to 3072 bytes (or more if you set a value for SEQPDL that is larger than the default of 4096). Otherwise you could get this error: ERROR 2126 USER'S PUSHDOWN LIST OVERFLOWED