MSIR.0903 (protocol) protocol error: Difference between revisions
Jump to navigation
Jump to search
(Created page with "A Janus connection using the indicated protocol encountered invalid data according to that protocol. The most common cause of the problem is a connection between a client and ser...") |
m (1 revision) |
(No difference)
|
Revision as of 16:45, 9 November 2010
A Janus connection using the indicated protocol encountered invalid data according to that protocol. The most common cause of the problem is a connection between a client and server using different protocols -- for example, a connection from a web client to a telnet server or from a SMTP client to a web server.
If this is believed not to be the case, contact Sirius Software technical support. To facilitate diagnosis of this problem, it is useful to reproduce the problem with a TCP trace -- TRACE set to 8 either on the JANUS DEFINE for the port or via the JANUS TRACE command.