AMPSUBZ parameter: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
|||
Line 20: | Line 20: | ||
On a z/OS system, <var class="product">Model 204</var> zIIP support enables you to offload <var class="product">Model 204</var> work from regular processors to zIIP processors.</p> | On a z/OS system, <var class="product">Model 204</var> zIIP support enables you to offload <var class="product">Model 204</var> work from regular processors to zIIP processors.</p> | ||
<p> | <p> | ||
<var>AMPSUBZ</var> specifies the number of active zIIP subtasks.</p> | <var>AMPSUBZ</var> specifies the number of active zIIP subtasks.</p> | ||
<p class="note"><b>Note:</b> MP subtasks and zIIP subtasks may be used together. Therefore, <var>[[AMPSUBS_parameter|AMPSUBS]]</var>, <var>[[NMPSUBS_parameter|NMPSUBS]]</var>, AMPSUBZ and <var>[[NMPSUBZ_parameter|NMPSUBZ]]</var> | <p>Do not set <var>AMPSUBZ</var> greater than the value of <var>[[NMPSUBZ_parameter|NMPSUBZ]]</var>.</p> | ||
<p class="note"><b>Note:</b> MP subtasks and zIIP subtasks may be used together. Therefore, <var>[[AMPSUBS_parameter|AMPSUBS]]</var>, <var>[[NMPSUBS_parameter|NMPSUBS]]</var>, AMPSUBZ and <var>[[NMPSUBZ_parameter|NMPSUBZ]]</var> can all be greater than zero. However, to avoid unnecessary overhead: </p> | |||
<ul> | <ul> | ||
<li> | <li> |
Revision as of 16:55, 8 June 2015
Number of active zIIP eligible subtasks
Summary
- Default value
- None
- Parameter type
- System
- Where set
- On User 0's parameter line or reset by system manager
- Related products
- All
- Introduced
- Model 204 V7.4
Description
Applies to z/OS only
On a z/OS system, Model 204 zIIP support enables you to offload Model 204 work from regular processors to zIIP processors.
AMPSUBZ specifies the number of active zIIP subtasks.
Do not set AMPSUBZ greater than the value of NMPSUBZ.
Note: MP subtasks and zIIP subtasks may be used together. Therefore, AMPSUBS, NMPSUBS, AMPSUBZ and NMPSUBZ can all be greater than zero. However, to avoid unnecessary overhead:
- Do not set AMPSUBS greater than the number of central processors actually available.
- Do not set AMPSUBZ greater than the number of zIIP processors actually available.
For more information about zIIP processing, refer to Offloading Model 204 work to zIIP processors.