<b> | <b>Max Backout Pages</b> | ||
==Summary== | ==Summary== | ||
<dl> | <dl> | ||
<dt>Default value | <dt>Default value | ||
<dd>-1 | <dd>-1 which is the same as 65535 (halfword X'FFFF') | ||
<dt>Maximum value | <dt>Maximum value | ||
<dd>65534 | <dd>65534 | ||
Line 14: | Line 14: | ||
</dl> | </dl> | ||
==Description== | ==Description== | ||
The maximum number of CCATEMP pages that one transaction can allocate for transaction backout. | |||
If MAXBOUT is exceeded, the request is cancelled with: | If MAXBOUT is exceeded, the request is cancelled with: | ||
<P> | <P><b> | ||
M204.0524: Maximum number (<number>) of MAXBOUT exceeded | M204.0524: Maximum number (<number>) of MAXBOUT exceeded | ||
</p> | </b></p> | ||
<p> | <p> | ||
Setting a value of -1 or 65535 | Setting a value of -1 or 65535 means that the number of TBO pages allocated for one transaction is unlimited. | ||
</p> | </p> |
Revision as of 00:23, 1 February 2018
Max Backout Pages
Summary
- Default value
- -1 which is the same as 65535 (halfword X'FFFF')
- Maximum value
- 65534
- Parameter type
- System
- Where set
- User 0 CCAIN parameters or reset by system manager
- Introduced
- V7.7
Description
The maximum number of CCATEMP pages that one transaction can allocate for transaction backout. If MAXBOUT is exceeded, the request is cancelled with:
M204.0524: Maximum number (<number>) of MAXBOUT exceeded
Setting a value of -1 or 65535 means that the number of TBO pages allocated for one transaction is unlimited.