Line 3: | Line 3: | ||
Model 204 does not recognize the version number of this password table. The reasons may be: </P> | Model 204 does not recognize the version number of this password table. The reasons may be: </P> | ||
<ul> | <ul> | ||
<li>The password table was created for a version of Model 204 that uses format incompatible with that expected by the current version of Model 204. </li> | <li>The password table was created for a version of Model 204 that uses a format incompatible with that expected by the current version of Model 204. </li> | ||
<li>The password table has been corrupted. </li> | <li>The password table has been corrupted. </li> | ||
Line 14: | Line 14: | ||
<li>Verify that the password table was created by a version of the ZBLDTAB utility compatible with the version of Model 204 you are running. If the versions are not compatible, you must re-create the table with a correct version of the ZBLDTAB utility or only use the table while running the version of Model 204 for which it is compatible. </li> | <li>Verify that the password table was created by a version of the ZBLDTAB utility compatible with the version of Model 204 you are running. If the versions are not compatible, you must re-create the table with a correct version of the ZBLDTAB utility or only use the table while running the version of Model 204 for which it is compatible. </li> | ||
<li>Verify that the data set containing the password table has not been corrupted by another job. If it has been corrupted, the table must | <li>Verify that the data set containing the password table has not been corrupted by another job. If it has been corrupted, the table must re-created. </li> | ||
<li>If neither case applies, Model 204 is incorrectly processing your password table. Contact [[Contacting Rocket Software Technical Support|Technical Support]]. </li> | <li>If neither case applies, Model 204 is incorrectly processing your password table. Contact [[Contacting Rocket Software Technical Support|Technical Support]]. </li> |
Revision as of 23:26, 22 February 2018
M204.0337 Wrong version for CCASTAT - hexVersion
Model 204 does not recognize the version number of this password table. The reasons may be:
- The password table was created for a version of Model 204 that uses a format incompatible with that expected by the current version of Model 204.
- The password table has been corrupted.
- Model 204 is incorrectly processing the table.
System manager response: Possible responses are as follows:
- Verify that the password table was created by a version of the ZBLDTAB utility compatible with the version of Model 204 you are running. If the versions are not compatible, you must re-create the table with a correct version of the ZBLDTAB utility or only use the table while running the version of Model 204 for which it is compatible.
- Verify that the data set containing the password table has not been corrupted by another job. If it has been corrupted, the table must re-created.
- If neither case applies, Model 204 is incorrectly processing your password table. Contact Technical Support.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |