M204.1365: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add <code>s) |
||
Line 1: | Line 1: | ||
{{Template:M204.1365 skeleton}} | {{Template:M204.1365 skeleton}} | ||
<P>You have encountered an unrecoverable system error. Model 204 will ask the operator if a full partition dump is to be taken and terminate with a return code of 100. </P> | <P> | ||
<p><b>System manager response:</b> The operator will be prompted to reply YES or NO to a Model 204 request on whether to take a full partition dump. If the operator replies NO, Model 204 will only terminate the run. [[Contacting Rocket Software Technical Support|Contact Technical Support]] and have the | You have encountered an unrecoverable system error. Model 204 will ask the operator if a full partition dump is to be taken and terminate with a return code of 100. </P> | ||
following documentation ready: </p><ul> | <p> | ||
<b>System manager response:</b> The operator will be prompted to reply <var>YES</var> or <var>NO</var> to a Model 204 request on whether to take a full partition dump. If the operator replies NO, Model 204 will only terminate the run. [[Contacting Rocket Software Technical Support|Contact Technical Support]] and have the following documentation ready: </p> | |||
<ul> | |||
<li>Audit trail </li> | <li>Audit trail </li> | ||
<li>Snap dumps, if any </li> | <li>Snap dumps, if any </li> | ||
<li>Full partition dump, if any </li> | <li>Full partition dump, if any </li> | ||
</ul><p><b>Operator response:</b> You will be prompted to reply YES or NO on whether Model 204 should take a full partition dump. Contact your system manager for directions. </p> | </ul> | ||
<p> | |||
<b>Operator response:</b> You will be prompted to reply <code>YES</code> or <code>NO</code> on whether Model 204 should take a full partition dump. Contact your system manager for directions. | |||
</p> | |||
{{Template:M204.1365 footer}} | {{Template:M204.1365 footer}} | ||
<!-- skeleton as it was in pdf/STXIT AB TRAPPED at module-name + offset /--> | <!-- skeleton as it was in pdf/STXIT AB TRAPPED at module-name + offset /--> |
Latest revision as of 23:38, 6 March 2018
M204.1365 STXIT AB trapped abendCode
You have encountered an unrecoverable system error. Model 204 will ask the operator if a full partition dump is to be taken and terminate with a return code of 100.
System manager response: The operator will be prompted to reply YES or NO to a Model 204 request on whether to take a full partition dump. If the operator replies NO, Model 204 will only terminate the run. Contact Technical Support and have the following documentation ready:
- Audit trail
- Snap dumps, if any
- Full partition dump, if any
Operator response: You will be prompted to reply YES
or NO
on whether Model 204 should take a full partition dump. Contact your system manager for directions.
Message attributes:
RETCODEO=100 | Sets online return code |
---|---|
RETCODEB=100 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |
SNAP | Generates a CCASNAP for the run |
DUMP | Generates a SYSUDUMP for the entire Model 204 region |