M204.1660: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add <var>s) |
||
Line 1: | Line 1: | ||
{{Template:M204.1660 skeleton}} | {{Template:M204.1660 skeleton}} | ||
<P> | <P> | ||
You specified a value for the ROUTER parameter on a USE PRINTER/PUNCH command that is invalid. ROUTER must be equal to <code>z/OS</code> when the operating system running Model 204 is z/OS. ROUTER must be equal to <code>POWER</code> when the | You specified a value for the <var>ROUTER</var> parameter on a <var>USE PRINTER/PUNCH</var> command that is invalid. <var>ROUTER</var> must be equal to <code>z/OS</code> when the operating system running Model 204 is z/OS. <var>ROUTER</var> must be equal to <code>POWER</code> when the | ||
operating system running Model 204 is z/VSE/POWER. </P> | operating system running Model 204 is z/VSE/POWER. </P> | ||
<p> | <p> | ||
<b>Response:</b> Specify a correct value for the ROUTER parameter, and retry the command. </p> | <b>Response:</b> Specify a correct value for the <var>ROUTER</var> parameter, and retry the command. | ||
</p> | |||
{{Template:M204.1660 footer}} | {{Template:M204.1660 footer}} | ||
<!-- skeleton as it was in pdf/ROUTER=router NOT SUPPORTED FOR THIS OPERATING SYSTEM /--> | <!-- skeleton as it was in pdf/ROUTER=router NOT SUPPORTED FOR THIS OPERATING SYSTEM /--> |
Latest revision as of 01:46, 9 March 2018
M204.1660 ROUTER=token not supported for this operating system
You specified a value for the ROUTER parameter on a USE PRINTER/PUNCH command that is invalid. ROUTER must be equal to z/OS
when the operating system running Model 204 is z/OS. ROUTER must be equal to POWER
when the
operating system running Model 204 is z/VSE/POWER.
Response: Specify a correct value for the ROUTER parameter, and retry the command.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |