<P> | <P> | ||
The data received, as a result of a | The data received, as a result of a <var>Receive</var> statement, has been truncated due to one of the following reasons: </P> | ||
<ul> | <ul> | ||
<li>The length of the data sent by the partner process is greater than the value of the DATALEN parameter, in the DEFINE PROCESS command, for this partner process. </li> | <li>The length of the data sent by the partner process is greater than the value of the <var>DATALEN</var> parameter, in the <var>DEFINE PROCESS</var> command, for this partner process. </li> | ||
<li>The length of the data sent by the partner process is greater than the length of the %variable specified in the | <li>The length of the data sent by the partner process is greater than the length of the %variable specified in the <var>Receive</var> statement. </li> | ||
</ul> | </ul> | ||
<p> | <p> | ||
<b>Response:</b> Correct the SOUL program or the partner process program by specifying a valid length. Otherwise, ask your system manager to increase the size of the DATALEN parameter in the DEFINE PROCESS command for your | <b>Response:</b> Correct the SOUL program or the partner process program by specifying a valid length. Otherwise, ask your system manager to increase the size of the <var>DATALEN</var> parameter in the <var>DEFINE PROCESS</var> command for your partner process. | ||
partner process. | |||
</p> | </p> | ||
{{Template:M204.1785 footer}} | {{Template:M204.1785 footer}} | ||
<!-- skeleton as it was in pdf/DATA RECEIVED HAS BEEN TRUNCATED /--> | <!-- skeleton as it was in pdf/DATA RECEIVED HAS BEEN TRUNCATED /--> |
Latest revision as of 18:59, 12 March 2018
M204.1785 Data received has been truncated
The data received, as a result of a Receive statement, has been truncated due to one of the following reasons:
- The length of the data sent by the partner process is greater than the value of the DATALEN parameter, in the DEFINE PROCESS command, for this partner process.
- The length of the data sent by the partner process is greater than the length of the %variable specified in the Receive statement.
Response: Correct the SOUL program or the partner process program by specifying a valid length. Otherwise, ask your system manager to increase the size of the DATALEN parameter in the DEFINE PROCESS command for your partner process.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
SAVE | Saves the message in the VIEW ERRORS table |