M204.2008: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add <var>s) |
||
Line 2: | Line 2: | ||
<P> | <P> | ||
IODEV=51 was specified in the CCAIN stream, but the LOCATION parameter was omitted. </P> | <code>IODEV=51</code> was specified in the CCAIN stream, but the <var>LOCATION</var> parameter was omitted. </P> | ||
<p> | <p> | ||
<b>Response:</b> Add the LOCATION parameter to your CCAIN stream before the IODEV line, and retry. | <b>Response:</b> Add the <var>LOCATION</var> parameter to your CCAIN stream before the <var>IODEV</var> line, and retry. | ||
</p> | </p> | ||
{{Template:M204.2008 footer}} | {{Template:M204.2008 footer}} | ||
<!-- skeleton as it was in pdf/LOCATION PARAMETER OMITTED /--> | <!-- skeleton as it was in pdf/LOCATION PARAMETER OMITTED /--> |
Revision as of 22:20, 14 March 2018
M204.2008 LOCATION parameter omitted
IODEV=51
was specified in the CCAIN stream, but the LOCATION parameter was omitted.
Response: Add the LOCATION parameter to your CCAIN stream before the IODEV line, and retry.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
OPR | Writes the message to the (operator) console |