M204.2610: Difference between revisions
(Automatically generated page update) |
No edit summary |
||
Line 1: | Line 1: | ||
{{Template:M204.2610 skeleton}} | {{Template:M204.2610 skeleton}} | ||
The M204.2610 text, <var class="term"> | The M204.2610 text, <var class="term">token</var>, begins as follows: | ||
<p class="output">System entered EXTENDED QUIESCE at: <var class="term">yy/ddd hh:mm:ss</var>, all file updating remains suspended </p> | <p class="output">System entered EXTENDED QUIESCE at: <var class="term">yy/ddd hh:mm:ss</var>, all file updating remains suspended </p> | ||
Latest revision as of 21:02, 30 March 2018
M204.2610 token
The M204.2610 text, token, begins as follows:
System entered EXTENDED QUIESCE at: yy/ddd hh:mm:ss, all file updating remains suspended
After this, one or two of the following are displayed, one each for waitType 47 and 48:
-- END EXTENDED QUIESCE processing is delayed with nnnn user(s) in wait type waitType
These END EXTENDED QUIESCE
phrases are displayed, first for waitType 47 and then for waitType 48, if the number of users in those wait types, respectively, is non-zero.
A Model 204 system that is in extended quiesce, presumably while file backups are being done, sends this informational message to the system operator every minute. The options indicate that a CHECKPOINT END EXTENDED QUIESCE
command is not immediate.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |