Revision as of 02:54, 22 June 2018
M204.2968 what: no debug info
An error message (immediately preceding M204.2968) was issued but insufficient compile-time information had been collected to provide the diagnostic information provided in the M204.2966 and M204.2967 messages. To get that additional information to help diagnose the problem, either set the SIRFCAT X'01' bit if authorized for SirFact or set the DEBUGUL parameter to a non-zero value. The latter requires no product authorization but does increase QTBL requirements.
Response: If unable to diagnose the problem, consider setting one of parameters described above to aid in problem diagnosis.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |