Summary
- Default value
- 21
- Parameter type
- System
- Where set
- On User 0's parameter line
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The number of bytes to be allocated in audit trail user statistics blocks for capturing the currently executing procedure name
The parameter can be reset to a maximum of 253 for long procedure names. A setting of 0 causes no space to be allocated in the statistics blocks and causes procedure names to appear as blanks on the audit trail.
Model 204 increases (if necessary) the setting of LAUDPROC to the nearest value that makes LAUDPROC + 3 a multiple of eight. The LAUDPROC parameter is always rounded up based on the following formula:
LAUDPROC = (LAUDPROC + 19 rounded to double word boundary)-19