MAXUD parameter: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
|||
Line 18: | Line 18: | ||
<p>Both backoutable update units and non-backoutable update units can become long update units.</p> | <p>Both backoutable update units and non-backoutable update units can become long update units.</p> | ||
<p>If MAXUD=0, <var class="product">Model 204</var> does not recognize long updates.</p> | <p>If MAXUD=0, <var class="product">Model 204</var> does not recognize long updates.</p> | ||
[[Category:System | [[Category:System Parameters]] | ||
[[Category:Parameters]] | [[Category:Parameters]] |
Revision as of 15:19, 19 April 2013
Summary
- Default value
- 0
- Parameter type
- System
- Where set
- On User 0's parameter line; not resettable
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The number of milliseconds beyond which a user's update unit is counted as a long update unit
The number of long update units and the total duration in milliseconds of all long update units are kept per user for user, since-last, and system statistics. Long update units are not tracked per file.
The update unit is considered to have started at the time of update of the first, local, non-HLI file, and to end at commit or backout.
Both backoutable update units and non-backoutable update units can become long update units.
If MAXUD=0, Model 204 does not recognize long updates.