Summary

Default value
0
Parameter type
System
Where set
On User 0's parameter line
Related products
All
Introduced
Model 204 V6.1 or earlier

Description

The action Model 204 takes when the number of consecutive failed attempts at logging in exceeds the value of the LOGTRY parameter

Valid settings of LOGFAIL are (options can be summed):

SettingMeaning
1Issue an error message identifying the user ID. The message is sent to the audit trail and the user's terminal.
2Deactivate the thread.