Revision as of 01:51, 23 April 2013
Summary
- Default value
- 0
- Parameter type
- System
- Where set
- On User 0's parameter line; not resettable
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The number of milliseconds beyond which a user's update unit is counted as a long update unit
The number of long update units and the total duration in milliseconds of all long update units are kept per user for user, since-last, and system statistics. Long update units are not tracked per file.
The update unit is considered to have started at the time of update of the first, local, non-HLI file, and to end at commit or backout.
Both backoutable update units and non-backoutable update units can become long update units.
If MAXUD=0, Model 204 does not recognize long updates.